What was found
MCD AFT HINGE LAST LUG CRACKED FROM EDGE TO FASTENER HOLE. REMOVED MCD AFT UPPER HINGE IAW FX DWG 52FX1433 REV E AND B727 SRM 51-30-2. LOCATED SHAPED AND DRILLED NEW HINGES SEGMENT 48 INCH BY 4 INCH IAW B727 SRM 51-30-5. TREATED AND PRIMED NEW PART IAW B727 SRM 51-10-2. INSTALLED NEW PART IAW B727 SRM 51-30-2. FAB NEW PIN FROM 5/16 303 COND B MIL-S-7720 IAW DRAWING NR 52FX1453 REV B. INSTALLED NEW PART IAW DWG NR 52FX1433 REV E AND B727 SRM 51-30-2.