What was found
FRAME STA 860 CRACKED BETWEEN STRINGER 3L AND 4L DAMAGE AREA 0.6" OUT LIMITS IAW 757 SF SRM 53-00-07. FABRICATED REPAIR CHANNELS -1,-2. REMOVED DAMAGE AREA IAW 757 SRM 53-00-07. INSTALLED REPAIR IAW SRM 53-00-07, REPAIR 3, FIG. 201. MAJOR REPAIR, CATEGORY "B".