What was found
MAIN DECK FLOOR SUPPORT CORRODED AT BS 345-365, LBL 60, L1 DOOR SILL. REMOVED CORROSION ON FLOOR SUPPORT IAW SRM 51-10-02 AT BS 345-365, LBL 60. REMOVED FLOOR SUPPORT IAW SRM 41-40-02. BLENDED AREA IS L=18.0", W=2.0", D=.015", OUT OF LIMITS PER SRM 53-00-51, FIG 101, DETAIL 3. FABRICATED NEW FLOOR SUPPORT ON MAE TRAVELER NR T9/777788. LOCATED, DRILLED, TREATED, PRIMED AND TOP COATED FLOOR SUPPORT PER SRM 51-40-05, 51-20-01, 51-20-00. INSTALLED REPAIR FLOOR SUPPORT AT BS 345-365, LBL 60, PER SRM 51-40-02. THIS REPAIR IS CLASSIFIED AS A CAT. "A" MAJOR REPAIR.