What was found
CABIN FLOOR SUPPORT ANGLE AT STA 790-755 RBL 64 HAS SPOTS OF SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-10-02, BLENDED AREA L=3" BY W=1.2" D=.O20". ORIGINAL MAT .063 INCH, REMAINING .040 INCH, OUT OF LIMITS AS PER SRM 53-30-13, FIG 101, DET II. REPLACED CREASE BEAM AT STA 755 TO 790 RT IAW SRM 51-40-02. CATEGORY "A", MAJOR REPAIR.