What was found
CORREDED LOWER SURFACE OF SUPPORT WEB ALONG RT EMERGENCY EXIT DOOR LOWER SILL AREA. REMOVED CORROSION IAW SRM 51-10-02 ON RT EMER EXIT DOOR LWR SILL, BLENDED AREA L=10.0" X W= 3.0" X D=0.020".ORIG MAT IS 0.063" MAT LOSS 0.048" AREA OUT OF LIMIT IAW SRM 53-60-15, DETAIL IV. REMOVED CREASE BEAM IAW SRM 51-40-02. FABRICATED WEB. INSTALLED WEB AND CREASE BEAM IAW SRM 51-40-02 AT BS 1320 - 1350, RBL 60. THIS REPAIR IS A CATEGORY "A" MAJOR REPAIR.