As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MCD INNER CENTER BEAM HAS MISDRILLED HOLE AND GOUGED INTO INTERCOSTAL REMOVED DAMAGE INTERCOSTAL IAW SRM 51-30-2, FABRICATED NEW INTERCOSTAL IAW HAYES INTERNATIONAL CORP DRAWING NR 52FX518 REV A, HEAT TREATED PART IAW FAS ENGINEERING REPORT NR 2-37153-801 REV A, TREATED AND PRIMED NEW INTERCOSTAL IAW SRM 51-10-2. INSTALLED NEW INTERCOSTAL AT MCK INNER CENTER BEAM IAW SRM 51-30-2.