What was found
FRAME CRACKED BS 990 ABOVE STR 26L AFT PIT. CUTOUT DAMAGED AREA IAW SRM 51-10-1, FABRICATED FILLER & DOUBLER IAW SRM 53-10-2 FIG 5 & 51-40-3 FIG 1. HEAT TREATED FILLER & DOUBLER TO 7075 T-6 IAW FAS ENG REPORT 2-37153-001 REV A. LOCATED DRILLED, DEBURRED FILLER & DOUBLER IAW SRM 51-40-3 FIG 1, 51-30-5, 51-30- 8. TREATED, PRIMED IAW SRM 51-30-2 INSTALLED IAW SRM 51-30-2.