What was found
FRAME CRACKED BS 970 ABOVE STR 26L AFT PIT. REMOVED INTERCOSTAL AND PREVIOUS REPAIR FOR ACCESS IAW SRM 51-30-2, CUTOUT DAMAGED AREA ON FRAME IAW SRM 51-10-1. FABRICATED FILLERS & DOUBLER IAW SRM 53-102 FIG 5 AND 51-40-3 FIG 1. HEAT TREATED FILLERS & DOUBLER TO 7075 T6 IAW FAS ENG REPORT 2-37153-801 REV A, LOCATED, DRILLED, DEBURRED FILLERS & DOUBLER IAW SRM 51-40-3 FIG 151-30-5, 51-30-8, TREATED & PRIMED IAW SRM 51-10-2, INSTALLED IAW SRM 51-30-2, INSTALLED INTERCOSTAL IAW SRM 51-30-2.