What was found
CABIN, LT STATION 1641, LONGERON 11 TO LONGERON 13 FRAME FOUND DENT. REPAIRED AS PER SRM 53-30-00 FIG. I VOL I. REPETITIVE INSPECTION REQUIRED, INITIAL AT 14,500 CYCLES AND REPETITIVE AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIG. I VOL I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.