What was found
AVIONICS COMPARTMENT RT UPPER FLOOR STRUCTURE BETWEEN FR 9 AND 10 INTERCOSTAL WEB HAS 1 INCH CRACK AT FWD LOWER CORNER. REMOVED AND FABRICATED WEB IAW DWG A553610270. INSTALLED WEB IAW A310-200 SRM 51-40- 21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AVIONICS COMPARTMENT RT UPPER FLOOR STRUCTURE BETWEEN FR 9 AND 10 INTERCOSTAL WEB HAS 1 INCH CRACK AT FWD LOWER CORNER. REMOVED AND FABRICATED WEB IAW DWG A553610270. INSTALLED WEB IAW A310-200 SRM 51-40- 21.