What was found
MAIN CARGO DECK FLOORBEAM UPPER 'T' BS 1030 HAS CORROSION BETWEEN LBL 0 AND LBL 25 FABRICATED ANGLES REPAIRS FOR FLOORBEAM UPPER 'T' ON MAE TRAVELER T9/783860 IAW WITH SRM 53-10-8, FABRICATED 2 FILLERS BATCH NR 000104977, TREATED AND PRIMED ANGLES REPAIRS, FILLERS IAW SRM 51-10-2 AND INSTALLED IAW SRM 51-30-2.