What was found
CABIN, LT STA 1701 LONGERON FRAME DOUBLER FOUND DENTED. REPAIRED AS PER SRM 53-30-00 FIG. I VOL. I REV. 40. REPETITIVE INSPECTION REQUIRED INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIG. I VOL. I REV. 40. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REV. 107.