As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
THE MAIN DECK FLOORBEAMS ARE CORRODED AT FRAME C-14; RBL 36. REMOVED CORROSION IN REF TO SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-12-15. REMOVED FLOORBEAM IAW SRM 51-72-10 PG 2. DRILLED NEW SUPPORT IAW SRM 51-72-10 PG 2. INSTALLED NEW FLOORBEAM SUPPORT IAW SRM 51-40-21& SRM 51-72-10 PG 2.