What was found
DENT, MAIN FRAME STA5-73 BETWEEN S-12R TO S-13R. REPAIRED AS PER SRM 53-30-00 FIGURE 1, VOLUME I, REVISION 40. REPETITIVE INSPECTION REQUIRE. INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIGURE 1, VOLUME I, REVISION 40. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100, REVISION 107.