What was found
STA 1640, AFT SIDE OF FRAME CORRODED BETWEEN STRINGER 26R AND 26L. CORROSION RUNNING INTO TRANSITION PANELS, U-CHANNELS AND VERTICAL SUPPORT STIFFENERS. REPLACED IAW SRM 51-40-02. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.