What was found
04 FASTENER HOLES FOUND CRACKED INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION, AT RIGHT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS 690 AND STA XORS 700. FASTENER HOLES FOUND CRACKED INDICATION DURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION AT RT WING LOWER SKIN ACCESS DOOR CUT-OUT BETWEEN STATION XORS 690 AND XORS 700, REPAIRED AS PER EA 1-5710-127824, CLASSIFIED AS MINOR REPAIR AS PER GMM 6-2-100, REVISION 107.