What was found
CABIN, RT STA 1641 LONGERON 12 FRAME FOUND DENT. REPAIRED AS PER SRM 53-30-00 FIG. I VOL. I REV 40. REPETITIVE INSPECTION REQUIRED, INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER SRM 53-30-00 FIG. I VOL. I REV. 40. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REV. 107.