What was found
CRACKED INDICATION FOUND DURING HFEC OPEN HOLE INSPECTION ON 0.460 INCH HOLES AT MAIN CARGO DOOR LOWER JAMB NR 1 SUPPORT FITTING AT HOLES A, B, C AND D. SUPPORT FITTING REMOVED AND REPLACED AS PER SRM 51-31-01 VOLUME II REVISION 40 AND BUSHING REPAIR CARRIED OUT FOR FIRST AND SECOND LAYER WEBS AS PER SRM 53-50-00 FIGURE 10 VOLUME I REVISION 40. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 107.