What was found
PROTRUSION DENT AT BS 700-720, S-25R - S-26R. EVALUATED DENT ON EXT FUSELAGE SKIN; FOUND OUT OF LIMITS IAW SRM 53-00-01, FIG 201. TRIMMED DAMAGED SKIN AND FABRICATED REPAIR DOUBLER. TREATED AND PRIMED REPAIR DOUBLER AND BARE METAL IAW SRM 51-20-01. LOCATED, DRILLED AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-01, FIG 201, REPAIR NR 3. THIS REPAIR IS CLASSIFIED AS A CAT "B" MAJOR REPAIR WITH THE FOLLOWING FOLLOW UP TRACKING: INITIAL INSPECTION AT 37,500 FC; THEREAFTER EVERY 6,000 FC WITH HFEC.