What was found
KEEL BEAM LOWER T FITTING FOR FAIRING SUPPORT HAS CORROSION AT STA 955, BL0. CORROSION ON TEE FITTING FOUND EXCEEDED SRM LIMITS. FITTING REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
KEEL BEAM LOWER T FITTING FOR FAIRING SUPPORT HAS CORROSION AT STA 955, BL0. CORROSION ON TEE FITTING FOUND EXCEEDED SRM LIMITS. FITTING REMOVED AND REPLACED IAW SRM 51-40-02 REV. 97. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100.