What was found
FRAME 47 NDT INSPECTION REVEALS INDICATION AT HOLE "Q" LT SIDE. REAMED HOLE "Q", COLD WORKED, REAMED TO .6532 INCH AND INSTALLED FASTENER IAW EA NR 6-5710-127960.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 47 NDT INSPECTION REVEALS INDICATION AT HOLE "Q" LT SIDE. REAMED HOLE "Q", COLD WORKED, REAMED TO .6532 INCH AND INSTALLED FASTENER IAW EA NR 6-5710-127960.