What was found
FORWARD CARGO DOOR, STA 520, STRINGER 21L-22L, CRACK ON STUB FRAME EXTENSION RADIUS. REMOVED DAMAGED STUB FRAME AND INSTALLED NEW FABRICATED ONE IAW SRM 51-30-2, 51-20-1 AND DWG 53FX1350.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO DOOR, STA 520, STRINGER 21L-22L, CRACK ON STUB FRAME EXTENSION RADIUS. REMOVED DAMAGED STUB FRAME AND INSTALLED NEW FABRICATED ONE IAW SRM 51-30-2, 51-20-1 AND DWG 53FX1350.