What was found
SNAKE PIT FWD CARGO, CORROSION AT STR 27 R, STA 740. REMOVED SNAKE PIT FLOOR PANEL TO FOM IAW SRM 51-30-2. CUT OUT SECTION OF STRINGER FOR REPAIR IAW SRM 51-10-1 AND 53-10-3 FIGURE 1. CUT OUT 26.7500 INCH. FABRICATED NEW STRINGER SECTION AND FABRICATED STRINGER SPLICE IAW SRM 53-10-3 FIGURE 1 AND 51-30-5. TREATED AND PRIMED PARTS IAW SRM 51-10-2. INSTALLED REPAIR IAW SRM 53-10-3, FIGURE 1 AND 51-30-2. INSTALLED FLOOR PANEL IAW SRM 51-30-2.