What was found
MINOR CORROSION AT STA 879, WL 208.1, RBL 12.00 TO LBL 12.00 ON TOP SURFACE FLOORBEAM. REPAIR AT LBL 12 CARRIED OUT IAW SRM 53-00-51 REV 96 FIG 201 REPAIR 3. AT RBL 12, CORROSION REMOVED IAW SRM 51-10-02 REV 96, FOUND WITHIN LIMITS. REPAIR IS CLASSIFIED AS MAJOR PER GMM 6-2-100 CRITERIA.