What was found
CRACKED WEB FOUND AT STA 1320 TO STA 1340, LBL 24.75, WL 207.10. TO REPLACE WEB ANGLE. REMOVED AND REPLACE WEB (P/N 140N2506-1) AND ANGLE (PN 140N2505-5) AT STA 1320 TO STA 1340, LBL 24.75, WL 207.10 IAW DWG 140N2506, DWG 140N2505, AND SRM 51-40-02 REV. 96. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.