What was found
FOUND CHAFING MARKS ON SLAT NR 2 RT, LWR SKIN RIB 3-4 AND 2 EXISTING FASTENER INSTALLED , RIB 11-12. REPAIR PERFORMED BY BLEND OUT THE CHAFING MARKS , NDT FORM CRACK FREE CONDITION AND REMOVAL OF THE 2 ADDITIONAL FASTENERS , CHECK FOR CRACKS AND INSTALLING NSA1739E4 RIVETS IAW. RAS/FOK/068/2009 ISS A , APPROVED BY EA 6-5740-129181.