What was found
AFT CARGO COMPT, FRAME 1500 IS GOUGED BETWEEN S-26L / S-27L. FOUND FRAME DENTED ON UPPER FLANGE. NO DENTS ARE ALLOWED IN THIS AREA IAW SRM 53-00-07, FIG 101. TRIMMED DAMAGE IAW SRM 53-00-07, FIG 201, DETAIL 1. FABRICATED REPAIR J-SECTION. HFEC TRIMOUT AND FOUND NO CRACKS IAW NTM 51-00-01, PART 6. LOCATED AND DRILLED REPAIR PART AND COLD WORKED HOLES IAW SRM 53-00-07, FIG 201, REPAIR NR 5, STEP NR 8. TREATED AND PRIMED REPAIR PART IAW SRM 51-20-01. INSTALLED REPAIR J-SECTION ON FRAME 1500, BETWEEN S-25-27L, IAW SRM 53-00-07, FIG 201, DETAIL 1, REPAIR NR 5. THIS REPAIR IS CLASSIFIED AS A CAT. "B" MAJOR REPAIR.