What was found
BS 760 TO 840, LBL 24, CEILING SUPPORT CORRODED. CORROSION REMOVED AND FOUND EXCEEDED SRM ALLOWABLE DAMAGE LIMITS. STRAP REMOVED AND REPLACED IAW SRM 51-40-02 REV 97. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 760 TO 840, LBL 24, CEILING SUPPORT CORRODED. CORROSION REMOVED AND FOUND EXCEEDED SRM ALLOWABLE DAMAGE LIMITS. STRAP REMOVED AND REPLACED IAW SRM 51-40-02 REV 97. REPAIR IS CLASSIFIED AS MINOR PER GMM 6-2-100 CRITERIA.