What was found
AT BS 1340, STR 22R, SIDEWALL SUPPORT ANGLE DAMAGED. SIDEWALL ANGLE FOUND BADLY DEFORMED BEYOND SRM ALLOWABLE DAMAGE LIMITS. SUPPORT ANGLE REMOVED AND REPLACED IAW DWG 146N1008 SHT 4 REV- AND DWG 146N5405 SHT 1 REV A. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.