What was found
DURING OPEN HOLE INSP CRACKED FOUND ON LT SIDE BANJO FITTING SECOND FASTENER HOLE COMMON TO BANJO FITTING AND CARRY THROUGH STRUCTURE AFT ROW ON BANJO FITTING LAYER. REPAIR CARRIED OUT IAW EA 1-5530-132118. REPAIR CATEGORY B, ACCOMPLISH INITIAL INSP WITHIN 5400 FLIGHT CYCLES FROM EA RELEASE DATE (15 JULY 2009) AND REPETITIVELY THERE AFTER WITHIN 2700 FLIGHT CYCLE INTERVALS IAW DWG NR. SN10550000. REPAIR CLASSFIED AS MAJOR IAW GMM 6-2-100, REVISION 107.