What was found
EXISTING REPAIR AT FUSELAGE EXTERIOR, AFT OF CENTER CARGO DOOR CUTOUT, STA. 1811, LONGERON 39-R. EXISTING REPAIR AT FUSELAGE EXTERIOR, AFT OF CTR CARGO DOOR CUTOUT STA 1811, LONGERON 39-R EVALUATED AND FOUND NOT CARRIED OUT IAW SRM REPAIR SCHEME. SASCO 391. EXISTING REPAIR DOUBLERS REMOVED IAW SRM 51-33-01 VOL 2 REV 40 AND REPAIR CARRIED OUT IAW EA 1-5310-132170, REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100 REV. 107.