As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GREEN RSVR LO LEVEL ALERT. FOLLOWED ECAMS, MANUAL GEAR EXTENSION. OVERHEAD GAUGE SHOWED GOOD QUANTITY. AFTER SHUTDOWN, BOTH QUANTITY INDICATORS SHOW MAX QUANTITY. RESTORED LANDING GEAR TO NORMAL OPERATIONS IAW MM 32-33-00-2. REMOVED AND REPLACED GREEN SYS RESERVOIR QUANTITY TRANSMITTER IAW MM 29-31-11-4. SYS OP CK'D NORMAL. RUN BOTH ENGINES IAW JRH. CHECKED GREEN HYD SYS USING ENG AND ELECTRIC PUMPS. ALL PROVIDED NORMAL PRESSURE WITH NO ECAM ALERTS. ACFT OK FOR SERVICE.