AT BS 1680 LBL 53 BOTTOM OF TOP CHORD OF AFT PRESSURE DECK CORRODED. FLOORBEAM UPPER CHORD CORROSION FOUND EXCEEDED SRM REPAIR LIMITS. REPAIR CARRIED OUT IAW EA F-5310-126226. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT BS 1680 LBL 53 BOTTOM OF TOP CHORD OF AFT PRESSURE DECK CORRODED. FLOORBEAM UPPER CHORD CORROSION FOUND EXCEEDED SRM REPAIR LIMITS. REPAIR CARRIED OUT IAW EA F-5310-126226. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-100 CRITERIA.