What was found
PRODUCTION FOUND 2EA FLOORBEAM STIFFENERS WITH ELONGATED HOLES AT STA 680, LBL 24.75 AND 45.5. AT STA 680, LBL 24.75- LBL 45.5, REPAIR WAS ACCOMPLISHED, DUE TO DISCREPANCY EFFECTING THE PTF CONVERSION, ON MAE MOD W/C 118350496BZ2R02, WITH MAE EA 757-5335-16-F2153, REV DATED JUNE 25, 2009, AND ON MAE MOD W/C 118350497BZ2R04, WITH MAE EA 757-5335-16-F2152, REV DATED JUNE 24, 2009. THIS N/R IS FOR TRACKING PURPOSES ONLY. MAJOR REPAIR.