What was found
MAIN DECK - STA 1997 LONGERON 23L, LONGERON SPLICE SUSPECTED CRACKED. MAIN DECK-LONGERON 23L AT STA 1997. CRACKED LONGERON SPLICE REMOVE AND REPLACED IAW SRM 51-31-01 REVISION 41. NEW SPLICE FABRICATED IAW DWG AJC7253, REVISION C. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REVISION 107.