What was found
AFT CARGO COMPT. BS 1130 FRAME, PREVIOUS REPAIR DOUBLER IS GOUGED ABOVE STR 27R. REMOVED PREVIOUS REPAIR IAW SRM 51-30-2, FABRICATED ANGLE REPAIR FROM 7075 "O" .063 PO NR 9008655 DIM 12 INCH X 6 INCH IAW SRM 53-10-2, 51-30-5, 51-20-5 HEAT TREATED ANGLE FROM "O" TO "T6" CONDITION IAW FASI ENGINEERING REPORTS NR 2-37153-801 REV A, LOCATED AND DRILLED REPAIR IAW SRM 51-30-5, ALODINE AND PRIMED ANGLE IAW SRM 51-10-2 INSTALLED ANGLE REPAIR IAW SRM 51-40-3, AND 51-30-2.