What was found
CRACK FOUND APPROX 0.3 INCH DURING HFEC INSP AT RT LOWER VERTICAL STABILIZER BANJO FITTING ON THE FWD FLANGE, NR 3 LOWEST FASTENER AS MARKED. REPAIR IAW SRM55-30-02, FIG201, REV41. (MAJOR REPAIR).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND APPROX 0.3 INCH DURING HFEC INSP AT RT LOWER VERTICAL STABILIZER BANJO FITTING ON THE FWD FLANGE, NR 3 LOWEST FASTENER AS MARKED. REPAIR IAW SRM55-30-02, FIG201, REV41. (MAJOR REPAIR).