What was found
FWD CARGO FLOOR SUPPORT SPLICES (8 EACH) FOUND CORRODED AT STA 705 LBL 3, 8, 12, 16 AND RBL 3, 8, 12, 16. FLOOR SUPPORT SPLICES FOUND CORRODED BEYOND SRM ALLOWABLE DAMAGE LIMITS. SPLICES REMOVED AND REPLACED IAW SRM 51-40-02 REV 97. REPAIR IS CLASSIFIED AS MINOR IAW GMM 6-2-100 CRITERIA.