As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 2 PYLON "Y" DUCT HEAT SHIELD IS CRACKED AT THE LR FLANGE. REMOVED AND INSTALLED HEAT SHIELD IAW SRM 51-40-21. MATERIAL ID 2024-T3 IAW SRM 51-70-10; PG 102. ALODINED AMD PRIMED DOUBLER IAW SRM 51-40-2; PARA 6. STOPPED DRILLED IAW SRM 51-70-10; PG 102.