What was found
DURING LWR AFT CARGO DOOR OPERATION FOUND DOOR UNABLE TO CLOSE DUE TO INTERFERENCE AT FWD LWR CORNER. AFT CARGO DOOR REMOVED AND REINSTALLED IAW AMM 52-33-04-4 REVISION 64. AFT CARGO DOOR HINGE REPAIR BUSHING FABRICATED AND INSTALLED IAW SRM 52-30-16 FIG 101 REVISION 41. AFT CARGO DOOR ACTUATOR ASSY REMOVED AND REINSTALLED IAW AMM 52-33-01-4 REVISION 64. OPS TEST OF AFT CARGO DOOR ACTUATOR ASSY CARRIED OUT IAW AMM 52-33-01-4, REV 64. OPS TEST OF AFT CARGO DOOR CARRIED OUT IAW AMM 52-33-00 REVISION 64. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 107.