What was found
RT WING, INBD FLAP UPPER SKIN HAS 2EA CHAFE MARKS .2500 INCH X .1250 INCH AT RIB 8-20 INCHES FROM L/E. CUT OUT DAMAGE AREA, NO CRACKS IAW NDT, FABBED AND INSTALLED DOUBLER IAW SRM 57-50-00, FIG. 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING, INBD FLAP UPPER SKIN HAS 2EA CHAFE MARKS .2500 INCH X .1250 INCH AT RIB 8-20 INCHES FROM L/E. CUT OUT DAMAGE AREA, NO CRACKS IAW NDT, FABBED AND INSTALLED DOUBLER IAW SRM 57-50-00, FIG. 205.