What was found
FWD CARGO COMPT, INTERCOSTAL WEB BTW FS 820 AND 839, S-26R UPPER EDGE DAMAGED AT FASTENER HOLE, DAMAGE CLEANUP IS OUT OF LIMITS IAW SRM 53-00-04, DETAIL I, FIG 101. NOTE: DAMAGE CLEANUP WAS EXISTING. REMOVED TRANSITION PANEL IAW SRM 51-40-02 FOR ACCESS FROM STA 765 TO 846 RT SIDE, REMOVED DAMAGED INTERCOSTAL WEB IAW SRM 51-40-02. RECEIVED NEW INTERCOSTAL FROM FAB SHOP TRAVELER NR T9/805621, LOCATED AND DRILLED IAW SRM 51-40-05. TREATED AND PRIMED IAW SRM 51-20-01 AND INSTALLED NEW INTERCOSTAL WEB FROM STA 820 TO 839, S-26R IAW SRM 51-40-02. REINSTALLED TRANSITION PANEL IAW SRM 51-40-02. MINOR REPAIR.