What was found
THE APU AIR INLET DOOR ASSY FWD MOUNTING LAND ON EMPANAGE IS CORRODED. REMOVED DAMAGED SUPPORT IAW SRM 51-40-02, REMOVED CORROSION IAW SRM 51-10-02, CHECKED LIMITS ORIG MAT .100, BLENDED 2 EA AREAS 1.0" X 2.0" X .060" OUT OF LIMITS IAW SRM 53-80-05 FIG 101 DET 3, FABED NEW SUPPORT ON TRAVELER T9/805156 IAW DWG 148N3138, LOCATED AND DRILLED SUPPORT IAW SRM 51-40-05 AND INSTALLED IAW SRM 51- 40-02 THIS IS A MAJOR "A" REPAIR WITH NO FOLLOW-UP INSPECTIONS REQUIRED.