What was found
AFT CARGO DOOR; AFT DOOR CUTOUT CRACKED PROFILE AT FASTENER HOLE LWR AFT CORNER. REMOVED OLD PROFILE AND INSTALLED NEW PROFILE PO NR 664219.4 IAW SRM 51-40-21; PARA 5 AND 13. DRILLED NEW PROFILE IAW SRM 51-40-44; TABLE II.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO DOOR; AFT DOOR CUTOUT CRACKED PROFILE AT FASTENER HOLE LWR AFT CORNER. REMOVED OLD PROFILE AND INSTALLED NEW PROFILE PO NR 664219.4 IAW SRM 51-40-21; PARA 5 AND 13. DRILLED NEW PROFILE IAW SRM 51-40-44; TABLE II.