What was found
NR 2 ENG PYRAMID FITTING HAS CORROSION ON LWR SURFACE AND AFT LT MOUNT HOLE. REAMED LT AFT MOUNT HOLE SRM 54-51-81; FIG 104; SHEET 2 TO 0.965 IN 4TH OVER-SIZE. REMOVED 0.002 IN PITTING CORROSION IN LT AFT MOUNT HOLE BY LOCAL BLEND OUT SRM 54-51-81; FIG 104; SHEET 3. CLEANED LWR SURFACE BASE FITTING REF AMM 12-21-11. NO CORROSION NOTED. NOTED AREA OF DAMAGE TO PROTECTIVE ALUMINUM SPRAYING. ACCOMPLISHED HFEC INSP OF LT AFT MOUNT HOLE IAW NTM 51-00-21, PT 6. NO DEFECTS NOTED AT THIS TIME. CALCULATED AMP-HOURS AND ADHESION TEST GOOD IN 4 AREAS REF SRM 51-21-10. PRIMED CAD PLATE AREA REF SRM 54-51-81.