As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LBL 62 FLOORBOARD SUPPORT FS, 395-377 CORRODED REMOVED CORROSION IAW SRM 51-10-02. ORIGINAL MAT .050 MAT LOSS IS .050 FOUND TO BE OUT OF LIMITS IAW SRM 53-0051 FIG 101 DETAIL 2 RMOVED CREASE BEAM IAW SRM 51-40-02. FABED NEW ON TRAVELER NR T9/ 804601 IAW SRM 53-10-15-2 LOCATED, DRILLED AND INSTALLED IAW SRM 51-40-05 AND 51-40-02 ( INSTALLED NEW CREASE BEAM FROM FST 295-395 LBL 60 ) W/L 208 THIS IS A MAJOR " A" REPAIR NO FOLOW-UP INSP REQUIRED.