What was found
MAIN CARGO AREA, STA 450, STR 3L NO EDGE DISTANCE BETWEEN RIVET AND HOLE. REMOVED FASTENERS AND CUT OUT DAMAGED AREA, FABRICATED ONE FILLER, ONE PLATE, TWO PLATES, TWO PLATES AND INSTALLED IAW SRM 51-30-2, 53-10-3 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO AREA, STA 450, STR 3L NO EDGE DISTANCE BETWEEN RIVET AND HOLE. REMOVED FASTENERS AND CUT OUT DAMAGED AREA, FABRICATED ONE FILLER, ONE PLATE, TWO PLATES, TWO PLATES AND INSTALLED IAW SRM 51-30-2, 53-10-3 AND 51-10-2.