What was found
L-1 ENTRANCE WALK WAY BS 300-340, LBL 56- RBL 30, FLOOR SUPPORTS LWR SURFACES HAVE CORROSION AT N/P HOLES AS MARKED. REMOVED CORROSION AND FOUND OUT OF LIMITS, CUT OUT DAMAGED AREA DIMS 2" X 1", FABRICATED 2 EACH REPAIR ANGLES USING 7075-0 .063 PO 9008655 DIMS 12" X 1" X 1" AND 10 1/8" X 1" X 1" AND 1 REPAIR FILLER USING 2024T-3 .063 PO 9008963, HEAT TREATED REQUIRED PARTS TO T-6 CONDITION IAW FASI FORM 2-37153-801 REV A AND INSTALLED PARTS IAW SRM 53-10-1, 51-10-2 AND DWG SR27-53-017 REV A.