What was found
MAIN CABIN, STA 345-365, APROX BL0 FLOOR SUPPORT HAS CORROSION. BLENDED AREA IAW SRM 51-10-02 DAMAGE L=1" X W=1" X D .010 FOUND TO BE OUT OF LIMITS IAE SRM 52-00-51 DETAIL 2, REMOVED FLOOR SUPPORT BETWEEN STA 345-365 AND FABRICATED 2 EA SUPPORT BRACKETS ON TRAV NR T9/ 806127 AND RECEIVE NEW SUPPORT PN BAC 1506-3384 AND INSTALLED PARTS IAW SRM 51-40-02, THIS IS A MAJOR "A" REPAIR NO FOLLOW-UP INSP REQUIRED.