What was found
RIGHT MAIN LANDING GEAR DOOR INTERNAL FASTENER IN CHAFING HINGE INBD OF THE ACTUATOR. (EA PURPOSE IS TO ALLOW THE BOLT & NUT INSTALLATION IN THE OPPOSITE DIRECTION FROM WHAT IS SHOWN IN THE AMM. THIS INSTALLATION DOES NOT AFFECT THE OPERATION OF THE SEQUENCE VALVE). DISCONNECTED RT MLG DOOR SEQUENCE VALVE CONTROL ROD PER AMM 32-12-11-4. DISCONNECTED R/H MLG SEQUENCE VALVE CONTROL ROD AT THE BELLCRANK PER AMM 32-12-11-4. SMOOTHED AREA PER SRM 51-73-10. ORIG THICKNESS .117, REMOVED .002, REMAINING .115. WITHIN LIMITS PER DWG NSA 2110. ALODINED PER SRM 51-21-10, P 3. PRIMED & PAINTED PER SRM 51-23-10, P 24. RECONNECTED RT MLG DOOR SEQUENCE VALVE RODS & PERFORMED CLEARANCE CHECK PER AMM 32-31-37-4, EA 6-3210-127990. CHECKS GOOD.